Detection of Data from Local System

Technique Detected:  Data from Local System | T0893

ID: DET0749
Domains: ICS
Analytics: AN1881, AN2137, AN2174, AN2244
Version: 1.0
Created: 21 October 2025
Last Modified: 13 October 2026

Analytics

AN1881

Monitor Windows Security Event ID 4663 on explicitly audited ICS data paths and correlate repeated ReadData/ListDirectory access across multiple sensitive files or directories by an account/process outside the approved engineering, backup, or application baseline. This requires Object Access auditing and SACLs on the monitored paths; Sysmon does not provide generic file-read telemetry. Alert when the bulk-read pattern occurs outside an approved backup/export window or is followed by staging, compression, or network transfer.

Log Sources
Data Component Name Channel
File Access (DC0055) WinEventLog:Sysmon Sequential file reads across multiple Industrial Control Systems (ICS) data paths by image not in authorized ICS applications, exceeding bulk access threshold within a short window
Process Creation (DC0032) WinEventLog:Sysmon EventCode=1 of archive utility immediately following bulk file access pattern from same parent process tree
Mutable Elements
Field Description
AuthorizedICSApplications Allowlist of processes expected to perform legitimate bulk reads of ICS data.
BulkAccessThreshold Number of distinct files read within the detection window that constitutes bulk collection.
ICSDataPaths File system paths containing ICS configuration, project, and sensitive operational data.

AN2137

Real-time monitoring identifies a Linux process performing sequential reads across multiple ICS configuration or data paths by a UID outside approved backup, engineering, or vendor-application accounts. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Log Sources
Data Component Name Channel
Command Execution (DC0064) auditd:SYSCALL Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): sequential reads across ICS data paths by uid not in authorized data access UIDs, followed by tar/zip invocation within a short window
Mutable Elements
Field Description
AuthorizedICSApplications Allowlist of processes expected to perform legitimate bulk reads of ICS data.
BulkAccessThreshold Number of distinct files read within the detection window that constitutes bulk collection.
ICSDataPaths File system paths containing ICS configuration, project, and sensitive operational data.

AN2174

Real-time monitoring identifies large outbound data transfers from Industrial Control System (ICS) server Internet Protocol (IP) addresses to destinations outside the approved ICS zone, following a pattern of bulk reads from engineering document stores or historian databases. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Log Sources
Data Component Name Channel
Network Traffic Flow (DC0078) netflow:ipfix IPFIX/NetFlow flow record (src/dst IP, src/dst port, protocol, packets/bytes/time): sustained high-byte-count flow from Industrial Control Systems (ICS) server Internet Protocol (IP) address to destination outside ICS zone following bulk read activity
Mutable Elements
Field Description
AuthorizedICSApplications Allowlist of processes expected to perform legitimate bulk reads of ICS data.
BulkAccessThreshold Number of distinct files read within the detection window that constitutes bulk collection.
ICSDataPaths File system paths containing ICS configuration, project, and sensitive operational data.

AN2244

Real-time monitoring identifies Industrial Control System (ICS) protocol sessions that bulk-read configuration data, program blocks, or data record objects from field devices -- function code sequences retrieving entire data dictionaries rather than operational process values -- from a source with no prior history of configuration-read sessions. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Log Sources
Data Component Name Channel
Network Traffic Content (DC0085) NSM:Content bulk read of configuration/data dictionary objects from source with no prior session history with this device
Mutable Elements
Field Description
AuthorizedICSApplications Allowlist of processes expected to perform legitimate bulk reads of ICS data.
BulkAccessThreshold Number of distinct files read within the detection window that constitutes bulk collection.
ICSDataPaths File system paths containing ICS configuration, project, and sensitive operational data.